QTP-X3S634201 42 Outlet Switched PDU 3 Phase 63A / 208V -F-tone

QTP-X3S634201 42 Outlet Switched PDU 3 Phase 63A / 208V -F-tone

Transceivers Type

SFP Optical Transceiver

Specifications

QTP-X3S634201 42 Outlet Switched PDU 3 Phase 63A / 208V

     

The QTP-X3S634201 PDU offers input and outlet level power and current monitoring, along with switching of each outlet as well as the PDU input.  Temperature and humidity sensors allow monitoring. Ethernet interface supporting cascaded or daisy chained devices, and is a local LCD display for on-site visibility.

  

Output Connectors 30x C13 + 12x C19 Output 22.7 kW, 63A, 3 phase
Output Circuit Breaker Specs 16A per outlet bank both C13 and C19 Wire Spec 4/4 AWG
Input Plug Type IEC 60309 3P+PE Input Cable Length 3 meters
Input Voltage 200-240V Network Connection 5x RJ45 ethernet ports with cascaded network devices
Network Speeds 10 and 100 Mbps Network Protocols DHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, SSH, SMTP, SNMP (v1/v2c/v3), and more.
Warranty 5 years Environmental Sensors Temperature and Humidity
Product Certifications UL 62368-1, CE, FCC, RoHS, and more Alarms Input current, output current, temperature, and humidity limits

Important Notice

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.

View full details

About F-tone Networks

F-tone Networks is now a world leader in development of optical transceivers and provide a wide range of high-speed optical solutions for optical communication networking, especially for AI, Data Center, enterprise data networking, Industry, aerospace, mining, shipbuilding, railway, metro, long haul transport networking, and mobile access networking applications
F-tone Networks invested in foundational photonics technologies and extensive product development and engineering with global presence in many area also.

Power and Wavelength Testing

Test the signal delivering strength and wavelength, to ensure the signal decoding capacity of the receiver, and the wavelength remains consistent from the transmitter to the receiver.

Power and Wavelength Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Traffic Testing

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

Optical Performance Testing

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

End Face Testing

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.

Various Switch Tests